宇宙環境下において,人工衛星自身の有機材料から放出rnされるアウトガス分子(低分子有機物)はより低温の表面rnへ付着する.付着物は,光学系の太陽光吸収率の増加や反rn射率・透過率の変化を引き起こし,ミッションへ悪影響をrn及ぼすことが知られている.%The Hinode (Solar-B) was launched by M-V rocket on 22 September 2006 UT. The telemetry data of the Hinode X-ray Telescope (XRT) showed that the X-ray count rate detected with the XRT had decreased rapidly since the operational heaters on the XRT telescope tube were turned on. This is attributed to the fact that molecular contaminants accumulated onto the CCD with the temperature of -60℃ resulting in the degradation of the XRT sensitivity. We baked the CCD at the temperature of 35℃ in order to remove the contaminants from the CCD surface. However many contaminant spots appeared on the surface. We found that major contaminant source existed in the telescope tube, and identified the contaminants as diethylhexyl phthalate (DEHP) or DEHP-like organics. The mechanisms to yield the contaminant spots were discussed.
机译:在太空环境中,从卫星自身的有机材料发出的废气分子(低分子量有机物)会附着在较低温度的表面rn上。已知沉积物导致光学系统的太阳吸收率增加并且抗rn发射率/透射率改变,这对任务有不利影响。 %Hinode(Solar-B)是由MV火箭于UT在2006年9月22日发射的.Hinode X射线望远镜(XRT)的遥测数据表明,自XRT投入运行以来,XRT探测到的X射线计数率迅速下降开启XRT望远镜筒上的加热器。这是由于分子污染物在-60℃的温度下积累到CCD上导致XRT灵敏度降低的事实。我们在35℃的温度下烘烤CCD。我们发现望远镜筒中存在主要污染物源,并将污染物鉴定为邻苯二甲酸二乙基己基酯(DEHP)或类DEHP的有机物,并提出了从CCD表面去除污染物的机制。讨论了污染点的产生。