首页> 外文期刊>Journal of Contaminant Hydrology >Reply to comment on 'Validation of two innovative methods to measure contaminant mass flux in groundwater' by Goltz et al. (2009)
【24h】

Reply to comment on 'Validation of two innovative methods to measure contaminant mass flux in groundwater' by Goltz et al. (2009)

机译:Goltz等人对“两种测量地下水污染物质量通量的创新方法的验证”的评论答复。 (2009年)

获取原文
获取原文并翻译 | 示例
           

摘要

We thank Sun (2014) for his comment on our paper, Goltz et al. (2009). The commenter basically makes two points: (1) equation (6) in Goltz et al. (2009) is incorrect, and (2) screen loss should be further considered as a source of error in the modified integral pump test (MIPT) experiment. We will address each of these points, below.
机译:感谢Sun(2014)对我们的论文Goltz等的评论。 (2009)。评论者基本上提出两点:(1)Goltz等人的等式(6)。 (2009)是不正确的,并且(2)在改进的整体泵测试(MIPT)实验中,滤网损失应进一步视为错误的来源。我们将在下面解决所有这些问题。