首页> 外文期刊>Institution of engineers journal (Inida) >Solid Desiccant Cooling System Employed with Ventilation Cycle: A Sensitivity Analysis
【24h】

Solid Desiccant Cooling System Employed with Ventilation Cycle: A Sensitivity Analysis

机译:使用通风循环的固体干燥剂冷却系统:灵敏度分析

获取原文
获取原文并翻译 | 示例
           

摘要

For better use of evaporative cooling techniques in humid climate, employment of desiccant cooling system (DCS) can be a suitable option. Desiccant augmented evaporative cooling system may be employed for energy saving in buildings in place of conventional vapour compression based cooling system. This article presents a sensitive analysis of DCS simulated under the humid climate of Mumbai, India. Mathematical computations have been performed using outdoor specific humidity, ambient dry bulb temperature and room supply temperature. A sensitive analysis considering some important forcing parameters was conducted. It was observed that the "effectiveness" of direct evaporative cooler to be predominantly high influencing parameter compared to others, for the performance of DCS.
机译:为了在潮湿气候中更好地使用蒸发冷却技术,可以选择使用干燥剂冷却系统(DCS)。干燥剂增强的蒸发冷却系统可以代替常规的基于蒸气压缩的冷却系统用于建筑物中的节能。本文介绍了在印度孟买潮湿气候下模拟的DCS的敏感分析。使用室外比湿度,周围干球温度和室内温度进行了数学计算。进行了考虑一些重要强迫参数的敏感分析。据观察,对于DCS的性能而言,直接蒸发式冷却器的“有效性”与其他参数相比主要是较高的影响参数。