Two cases are reported in which, after ACL reconstruction with autologous hamstring grafts, tibial polylactide interference screws migrated into the knee joint. Clinically, both patients presented with recurrent locking of the joint. In one case, a broken 15 mm-long tip of the screw was found intra-articularly. In the other case, the whole screw had migrated into the joint cavity. The degradation process of polylactic acid, operative technique and bone quality are discussed as possible reasons for these complications.
机译:报告了两例,其中用自体腿筋移植重建ACL后,胫骨聚乳酸干扰螺钉移入膝关节。在临床上,两名患者均表现为关节反复锁定。在一种情况下,在关节内发现了15毫米长的断头。在另一种情况下,整个螺钉已移入关节腔。讨论了聚乳酸的降解过程,手术技术和骨质可能是这些并发症的可能原因。