首页> 外文期刊>Medecine Nucleaire >The hypersensitivity to low-dose phenomenon: One radiobiology enigma finally resolved?
【24h】

The hypersensitivity to low-dose phenomenon: One radiobiology enigma finally resolved?

机译:对低剂量现象的超敏性:一个放射生物学的谜团终于解决了?

获取原文
获取原文并翻译 | 示例
           

摘要

Hypersensitivity to low-dose of ionising radiation (HRS) is a well-documented phenomenon that illustrates well a biological non-linearly dose dependent effect where the molecular and cellular events observed in a low-dose range (generally from 1 mGy to 0.8 Gy) are similar to those observed in 5-50 times higher doses. Up to now, the HRS phenomenon remained unexplained. Since 2003, we accumulated a large number of individual radiosensitivity cases whether well characterized genetically or revealed after postradiotherapy tissue reactions: after a dose of 2 Gy (one standard radiotherapy session), we pointed out that the ATM protein shuttles from cytoplasm to nucleus to activate the DNA double-strand breaks repair. The more efficient the transit, the higher the radioresistance. Here, we provided evidence that the transit of ATM can explain the HRS phenomenon, whose consideration may change the estimation of the risk linked to low-dose radiation. (C) 2016 Elsevier Masson SAS. All rights reserved.
机译:对低剂量电离辐射(HRS)的超敏反应是一个有据可查的现象,充分说明了生物学非线性剂量依赖性效应,其中在低剂量范围内观察到的分子和细胞事件(通常为1 mGy至0.8 Gy)与在5至50倍高剂量下观察到的相似。到目前为止,HRS现象仍无法解释。自2003年以来,我们积累了大量个体放射敏感性病例,无论是在遗传学上已经很好地表征还是在放射治疗后的组织反应后可见:在2 Gy剂量(一次标准放射治疗)后,我们指出ATM蛋白从细胞质穿梭到细胞核以激活DNA双链断裂修复。运输效率越高,抗辐射性越高。在这里,我们提供了证据表明ATM的运输可以解释HRS现象,其考虑可能会改变与低剂量辐射有关的风险的估计。 (C)2016 Elsevier Masson SAS。版权所有。

著录项

  • 来源
    《Medecine Nucleaire》 |2016年第3期|254-257|共4页
  • 作者单位

    INSERM, Canc Res Ctr Lyon, Ctr Rech Cancerol Lyon, UMR1052,Grp Radiobiol, Batiment Cheney A,Rue Laennec, F-69008 Lyon, France;

    INSERM, Canc Res Ctr Lyon, Ctr Rech Cancerol Lyon, UMR1052,Grp Radiobiol, Batiment Cheney A,Rue Laennec, F-69008 Lyon, France;

    INSERM, Canc Res Ctr Lyon, Ctr Rech Cancerol Lyon, UMR1052,Grp Radiobiol, Batiment Cheney A,Rue Laennec, F-69008 Lyon, France;

    INSERM, Canc Res Ctr Lyon, Ctr Rech Cancerol Lyon, UMR1052,Grp Radiobiol, Batiment Cheney A,Rue Laennec, F-69008 Lyon, France;

    INSERM, Canc Res Ctr Lyon, Ctr Rech Cancerol Lyon, UMR1052,Grp Radiobiol, Batiment Cheney A,Rue Laennec, F-69008 Lyon, France;

    Inst Radioprotect & Surete Nucl, Fontenay Aux Roses, France;

    INSERM, Canc Res Ctr Lyon, Ctr Rech Cancerol Lyon, UMR1052,Grp Radiobiol, Batiment Cheney A,Rue Laennec, F-69008 Lyon, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 fre
  • 中图分类
  • 关键词

    Low dose; Radiosensitivity; ATM; DNA repair;

    机译:低剂量;放射敏感性;ATM;DNA修复;