首页> 外文期刊>Pipeline & gas journal >A Redundant, Immune, Calibrated Gas Detector
【24h】

A Redundant, Immune, Calibrated Gas Detector

机译:冗余的免疫校准气体检测仪

获取原文
获取原文并翻译 | 示例
           

摘要

OptoAcoustic gas detection determines gas content via the measurement of acoustic pressure waves that are propagated as a gas is irradiated under an appropriately tuned light. A gaseous mixture sample passes through a membrane into a measurement cell, which contains an optical light source and a microphone. Incident light modulated at a specific frequency is briefly absorbed as intermolecular energy by the gas molecules and then released as translational energy, creating periodic temperature and pressure changes that generate measurable acoustic pulses.
机译:光声气体检测通过测量在适当调谐的光下照射气体时传播的声压波来确定气体含量。气体混合物样品穿过膜进入测量池,该测量池包含一个光学光源和一个麦克风。以特定频率调制的入射光被气体分子短暂吸收为分子间能量,然后释放为平移能量,从而产生周期性的温度和压力变化,从而产生可测量的声脉冲。

著录项

  • 来源
    《Pipeline & gas journal》 |2012年第10期|98-98|共1页
  • 作者

    Mourad Baraket;

  • 作者单位

    Carthago International Solutions, Inc., New York City;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);