This paper presents a digital simulation of an active filter, in which the instantaneous harmonic and reactive compensating currents are desegregated in their different /spl alpha//spl beta/ space-trajectories, and in their time-domain waveforms of both the abc and the /spl alpha//spl beta/ system of coordinates. Departing from Akagi's generalized instantaneous reactive power theory, a complete analysis is presented, in which the counterharmonic compensating current injected to the coupling point of the AC mains feeding a six-pulse-controlled three phase AC/DC power converter is desegregated in its three components, namely: (a) fundamental reactive current; (b) oscillating harmonic reactive current; and (c) oscillating harmonic active current. It is demonstrated, in a selected number of abc and /spl alpha//spl beta/ oscillograms and current-space-trajectories that the active filter can compensate either separately or jointly the above mentioned currents.
机译:本文介绍了一个有源滤波器的数字仿真,其中瞬时谐波和无功补偿电流在其不同的/ spl alpha // spl beta /空间轨迹上以及在其abc和a的时域波形中被分解。 / spl alpha // spl beta /坐标系。与Akagi的广义瞬时无功功率理论不同,本文进行了完整的分析,其中将注入到六脉冲控制的三相AC / DC电源转换器的交流电源耦合点注入的反谐波补偿电流分解为三个分量。即:(a)基本无功电流; (b)振荡谐波无功电流; (c)振荡谐​​波有功电流。在选定数量的abc和/ spl alpha // spl beta /波形图和电流空间轨迹中证明,有源滤波器可以单独或共同补偿上述电流。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号