All 3-core cables require fillers to fill the space between insulated cores and the belt insulation or a sheath. The equations given in IEC 287 and in the Neher-McGrath paper (1957) for the internal thermal resistance of 3-core cables were developed for paper insulated cables. For such cables, it was assumed that the insulation and filler materials have the same thermal resistivities. In reality, in 3-core cables a variety of materials are used as fillers. The majority of these will have a higher thermal resistivity than the insulation. In the previous paper, a new formula was developed to compute the value of the internal thermal resistance of belted cables taking into account the thermal resistivity of the filler. In this paper, screened cables are considered and a new formula for the computation of the internal thermal resistance of such cables is presented. The effect of filler resistivity on cable ampacity is also discussed.
机译:所有3芯电缆都需要填充填充物,以填充绝缘芯与皮带绝缘或护套之间的空间。针对纸绝缘电缆,开发了IEC 287和Neher-McGrath论文(1957)中给出的有关3芯电缆内部热阻的方程。对于这种电缆,假定绝缘材料和填充材料具有相同的热阻率。实际上,在3芯电缆中,多种材料被用作填充物。其中大多数将具有比绝缘更高的热阻。在先前的论文中,考虑到填料的热阻系数,开发了一个新公式来计算带状电缆的内部热阻值。本文考虑了屏蔽电缆,并提出了一种计算此类电缆内部热阻的新公式。还讨论了填料电阻率对电缆载流量的影响。