首页> 外文期刊>Power Electronics, IET >Adaptive estimation of the transformer stray capacitances for DC–DC converter modelling
【24h】

Adaptive estimation of the transformer stray capacitances for DC–DC converter modelling

机译:用于DC-DC转换器建模的变压器杂散电容的自适应估计

获取原文
获取原文并翻译 | 示例
           

摘要

New low cost and accurate estimation method of transformer stray capacitances for wide band DC–DC converter modelling and design is proposed. The Wiener filter (WF) method is applied to estimate the transformer impedance – referred to the selected transformer winding configurations. Laboratory tests are used to adapt the filter, that is to find optimal impedance which minimises mean square error between measured, noise perturbed current and reconstructed current. Transformer transfer function peaks indicate internal LC resonances. Stray capacitances are extracted based on resonant frequencies determination. The method validation is carried out by simulation and experimental analysis, where estimated stray capacitances by WF are compared with measurements of an impedance analyser.
机译:针对宽带DC-DC变换器的建模和设计,提出了一种新的低成本,准确的变压器杂散电容估计方法。使用维纳滤波器(WF)方法来估计变压器阻抗-取决于所选的变压器绕组配置。实验室测试用于调整滤波器,即找到最佳阻抗,以最小化测量的,噪声干扰的电流和重构的电流之间的均方误差。变压器传递函数峰指示内部LC谐振。基于谐振频率确定来提取杂散电容。通过仿真和实验分析来进行方法验证,其中将WF估计的杂散电容与阻抗分析仪的测量值进行比较。