Some of the experimental conditions of JIS A 1905 "Performance test of adsorptive building materials of reducing indoor air pollution with small chamber" are different from the actual building environment. The agreement between a decreasing effect resulted from JIS test method and that under residential indoor environment is suspected. The optimum experimental conditions resulting true effect were investigated with an experimental design, Within the scope of the performance test with 0.15m~3 volume of a SUS small test chamber and a specimen of adsorptive building material in this study, appropriate experimental conditions are verified, namely optimum loading factor is 0.5m~2/m~3 and optimum supply HCHO concentration is 100μg/m~3.%(1)今回試験対象とした濃度低減建材に関しては,実際の住宅室内における濃度低減建材の低減性能を試験結果として得る上で必要としている試料設置率,及び,小型チャンバーへ供給するHCHO濃度の試験条件は,JIS A 1905-1「小形チャンバー法による室内空気汚染濃度低減材の低減性能試験法一第1部:一定ホルムアルデヒド濃度供給法による吸着速度測定」で規定している試験条件と異なっていた。
机译:JIS A 1905“以小室减少室内空气污染的吸附性建筑材料的性能测试”的一些实验条件与实际建筑环境不同。JIS测试方法产生的降低效果与住宅室内环境下的降低效果之间存在一致性。通过实验设计研究了产生真实效果的最佳实验条件。在本研究中,在0.15m〜3体积的SUS小测试室和吸附性建筑材料样品的性能测试范围内,适当的实验条件经过验证,即最佳负载因子为0.5m〜2 / m〜3和最佳供应HCHO浓度为100μg/ m〜3.%(1)实际建筑物中的浓度降低JIS A 1905-1“通过小室法减少室内空气污染浓度的降低材料”中描述了为获得建筑材料的降低性能而需要的提供给小室的样品安装率和HCHO浓度的测试条件。性能测试方法1:第1部分:“通过恒定甲醛浓度供应方法测量吸附率”与测试条件不同。