首页> 外文期刊>日本建築学会環境系論文集 >コージェネレーションシステムを用いた大学キャンパスにおけるエネルギー調査: 需要側の電力消費量の実態 その2
【24h】

コージェネレーションシステムを用いた大学キャンパスにおけるエネルギー調査: 需要側の電力消費量の実態 その2

机译:使用热电联产系统的大学校园能源调查:需求侧的实际能耗第二部分

获取原文
获取原文并翻译 | 示例
           

摘要

The end-use consumption of electricity in a university campus with co-generation system is investigated. According to the hourly data in classrooms, research laboratory, office rooms, and dining hall, the characteristics for electricity consumption in different buildings are analyzed. The office room consumes the largest amount of electricity of about 124.4kWh/(m~2a), then followed by the dining hall and then the research laboratory, both of about 114 kWh/(m~2a). The classroom consumes the smallest amount of about 60.6kWh/(m~2a). The difference between the peak and off-peak is quite large, and it is 6 times in research laboratory, while it is nearly 20 times in classrooms and dining hall. The duration of peak load is very short, while the operating frequency at partial load is quite high, which leads to large electricity consumption during the partial load rate. Furthermore, the monthly pattern and hour pattern of electricity consumption in different buildings are also analyzed.%本研究では、時刻別の電力消費データに基づいて理工系大学キャンパスにおける建物用途別の一般電力消費量を調査・解析した。事務室の電力消費量が最も大きく124.4kWh/(m~2.a)である。
机译:研究了利用热电联产系统的大学校园的最终用电量。根据教室,研究实验室,办公室和餐厅的小时数据,分析不同建筑物的用电量特征。办公室的耗电量最大,约为124.4kWh /(m〜2a),其次是餐厅,然后是研究实验室,两者的耗电量均为114kWh /(m〜2a)。教室的最小耗电量约为60.6kWh /(m〜2a)。高峰和非高峰之间的差异很大,在研究实验室中是高峰期的6倍,而在教室和餐厅中则接近20倍。峰值负载的持续时间很短,而部分负载下的工作频率很高,这导致在部分负载率下消耗大量电能。此外,还分析了不同建筑物的每月用电量和小时用电量。%本研究では,时刻别の电力消费データに基づいて理工系大学キャンパスにおける建物用途别の一般电力消费量を调查・解析した事务室の电力消费量が最も大きく124.4kWh /(m〜2.a)である。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号