首页> 外文期刊>Process Heating >When Temperature Measurement Goes Awry
【24h】

When Temperature Measurement Goes Awry

机译:温度测量出现问题时

获取原文
获取原文并翻译 | 示例
           

摘要

All contact temperatute sensors such as thermocouples, RTDs, etc., can suffer from the Stem Effect, which occurs when a probe is immersed in a heated gas, liquid or any hot zone. In these situations, heat is conducted away from the tip of the sensor (the portion that makes the measurement) along the sheath (or stem) of the probe to the outer atmosphere, resulting in a lower reading than reality.
机译:所有接触温度传感器(例如热电偶,RTD等)都可能遭受“干效应”(Stem Effect)的影响,这种效应发生在将探头浸入加热的气体,液体或任何热区中时。在这些情况下,热量从传感器的尖端(进行测量的部分)沿着探头的护套(或主干)传导到外部大气,导致读数低于实际情况。