Theoretical assessments of power density in far-field conditions were used to evaluate the levels of environmental electromagnetic frequencies from selected GSM900 macrocell base stations in the West Bank and Gaza Strip. Assessments were based on calculating the power densities using commercially available software (RF-Map from Telstra Research Laboratories-Australia). Calculations were carried out for single base stations with multiantenna systems and also for multiple base stations with multiantenna systems at 1.7 m above the ground level. More than 100 power density levels were calculated at different locations around the investigated base stations. These locations include areas accessible to the general public (schools, parks, residential areas, streets and areas around kindergartens). The maximum calculated electromagnetic emission level resulted from a single site was 0.413 µW cm~(-2) and found at Hizma town near Jerusalem. Average maximum power density from all single sites was 0.16 µW cm-2. The results of all calculated power density levels in 100 locations distributed over the West Bank and Gaza were nearly normally distributed with a peak value of ~0.01% of the International Commission on Non-Ionizing Radiation Protection's limit recommended for general public. Comparison between calculated and experimentally measured value of maximum power density from a base station showed that calculations overestimate the actual measured power density by ~27%.
机译:对远场条件下的功率密度进行了理论评估,以评估西岸和加沙地带选定GSM900宏蜂窝基站的环境电磁频率水平。评估是基于使用市售软件(澳大利亚Telstra研究实验室的RF-Map)计算功率密度而进行的。对于具有多天线系统的单个基站以及在高于地面1.7 m的具有多天线系统的多个基站进行了计算。在被调查基站周围的不同位置计算出了100多个功率密度。这些地点包括公众可进入的区域(学校,公园,住宅区,街道和幼儿园附近的区域)。在耶路撒冷附近的伊兹马镇发现的单个地点的最大计算电磁辐射水平为0.413 µW cm〜(-2)。来自所有单个站点的平均最大功率密度为0.16 µW cm-2。在西岸和加沙地带分布的100个位置中,所有计算出的功率密度水平的结果几乎都呈正态分布,其峰值约为国际非电离辐射防护委员会向公众推荐的限值的0.01%。对基站的最大功率密度的计算值和实验测量值之间的比较表明,计算结果将实际测得的功率密度高估了约27%。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2017年第1期|74-78|共5页
  • 作者单位

    Center for Radiation Science & Technology, Al-Quds University, PO Box 20002, East Jerusalem, Palestine;

    Center for Radiation Science & Technology, Al-Quds University, PO Box 20002, East Jerusalem, Palestine;

    Center for Radiation Science & Technology, Al-Quds University, PO Box 20002, East Jerusalem, Palestine , Medical Imaging Department, Al-Quds University, PO Box 20002, East Jerusalem, Palestine;