Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover, Germany), ImPACT CT Patients Dosimetry Calculator (version 0.99 ×, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck, Germany), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen, Germany) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen, Germany) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly.
机译:计算机断层扫描(CT)剂量报告软件有助于估计接受CT检查的患者的剂量。在这项研究中,比较了三个软件包,即CT-Expo(1.5版,德国汉诺威的Medizinische Hochschule),ImPACT CT患者剂量计算器(0.99×,计算机断层扫描成像性能评估,www.impactscan.org)和WinDose(版本2.1a,德国Schwarzenbruck的Wellhofer剂量法)是根据其计算算法和计算剂量的结果制成的。根据欧洲指南推荐的方案,使用单层CT(SSCT)(德国Sermens Somatom Plus 4,德国埃尔兰根)和多层CT(MSCT)(Siemens Sensation 16)对头,胸,腹和骨盆检查进行评估(位于德国埃尔兰根),用于基于软件的女性和男性幻像。结果表明,这些软件包提供的最终剂量报告存在一些差异。这些软件包产生的有效剂量存在偏差。在SSCT中,变异系数的百分比范围为3.3%至23.4%,在MSCT中,变异系数的百分比范围为10.6%至43.8%。研究人员必须说明用于估算各种CT剂量的软件的名称,这一点很重要。用户还必须了解从CT控制台获得的信息与软件包之间的等效术语,以便正确使用该软件。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2012年第1期|p.153-157|共5页
  • 作者单位

    Medical Physics, Comprehensive Cancer Center, King Fahad Medical City, PO Box 59046, Riyadh 11525, Saudi Arabia;

    Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, Perth, Western Australia 6845, Australia;

    Faculty of Medical Technology, Mahidol University, Bangkok 10700, Thailand;

    Department of Biomedical Imaging, University of Malaya, Kuala Lumpur 50603, Malaysia,University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur 50603, Malaysia;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号