摘要

A pulse‐shape discrimination system for use with organic scintillators is described which is based upon the true zero‐crossing detection of single delay‐line shaped pulses. Results of performance tests are presented in the form of contour diagrams which show the crossover‐time spectra of neutron and gamma‐ray induced events as a function of pulse amplitude. A technique to compensate for the variation of scintillation pulse shape with recoil‐proton energy is described. Good gamma‐ray rejection with nearly 100% recoil‐proton acceptance over a dynamic range of 100 is obtained.
机译:描述了一种与有机闪烁体一起使用的脉冲形状判别系统,该系统基于单个延迟线形状的脉冲的真正过零检测。性能测试的结果以等高线图的形式表示,这些图显示了中子和伽马射线诱发事件的穿越时间谱随脉冲幅度的变化。描述了一种利用反冲质子能量补偿闪烁脉冲形状变化的技术。在100的动态范围内获得了良好的伽马射线抑制能力,近100%的反冲质子接受能力。