This paper presents the author's method for the heat flux evaluation on the basis of a thermal photograph. This method is based on the comparison of surface temperatures of two areas where one of them is a thermally loaded with a known heat flux and the other control area which is not thermally loaded. With the method presented in the article analysing heat fluxes in places of high heat flux gradients occurring within heat leakage bridges, especially the service ones connected with the material humidity where heat flux density sensors can give substantial errors when the flux on the sensor surface is averaged.
机译:本文介绍了一种基于热像的热通量评估方法。该方法基于两个区域的表面温度的比较,其中两个区域之一的表面温度为已知热通量的热负荷,而另一个控制区域的温度为非热负荷。使用本文介绍的方法分析热泄漏桥中发生的高热通量梯度处的热通量,特别是与材料湿度有关的服务热源,当平均传感器表面上的热通量时,热通量密度传感器会产生很大的误差。