This study proposed a potentiometric non-enzymatic electrochemical sensor for glucose detection based on copper doped zinc oxide (CZO) as a sensing film. In this article, a metal oxide film was used, which was able to react catalytically with glucose. The wires of the sensor were prepared by screen printing technology, and the CZO thin film was deposited on the sensor by the radio frequency (R. F.) sputtering system. In order to make the non-enzymatic sensor more stable, Nafion layer was added to the working electrodes. The characteristics of the sensor were measured using a voltage time (V-T) measurement system. Average sensitivity and linearity of the Nafion/CZO glucose sensor was tested in glucose concentrations ranging from 2 mM - 14 mM. After experiment, it was confirmed that the sensor had good performance. Experiments confirmed that the Nafion/CZO sensor exhibited characteristics including: good selectivity for glucose, average sensitivity of 6.45 mV/mM, a linearity of 0.998, a response time of 20 sec, and a limit of detection (LOD) of 0.51 mM. The device has a low relative standard deviation (RSD) and would be suitable for further development and eventual use in biomedical applications.
机译:该研究提出了一种基于铜掺杂氧化锌(CZO)作为传感膜的葡萄糖检测电位非酶促电化学传感器。在本文中,使用金属氧化物膜,其能够用葡萄糖催化反应。通过丝网印刷技术制备传感器的电线,通过射频(R.F.)溅射系统在传感器上沉积CZO薄膜。为了使非酶促传感器更稳定地,将Nafion层加入到工作电极中。使用电压时间(V-T)测量系统测量传感器的特性。 Nafion / CZO葡萄糖传感器的平均敏感性和线性在葡萄糖浓度范围为2mm-14mm。实验后,证实传感器性能良好。实验证实,Nafion / CZO传感器表现出特征,包括:葡萄糖的良好选择性,平均灵敏度为6.45mV / mm,线性度为0.998,响应时间为20秒,检测(LOD)的响应时间为0.51mm。该设备具有低相对标准偏差(RSD),并且适用于进一步的开发和最终在生物医学应用中使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号