首页> 外文期刊>Solar Energy >The comparative field performance study of heat pipe evacuated tube collectors with standard design manifold header and parallel flow manifold header based on the metal foam structural element
【24h】

The comparative field performance study of heat pipe evacuated tube collectors with standard design manifold header and parallel flow manifold header based on the metal foam structural element

机译:基于金属泡沫结构元件的标准设计歧管集管和平行流歧管集管的热管真空管集热器的现场性能比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

The paper deals with an experimental thermal performance comparison of standard design heat pipe evacuated tube collector and collector with parallel flow manifold header with metal foam structural element which was developed by authors in their previous work. The used data were obtained during experimental simultaneous operation of two interconnected solar systems at the Centre of Renewable Energy Sources, Kosice, Slovakia during the months of April and May in various weather and climatic conditions. Manifold header with metal foam structural element partially eliminates deficiencies of standard design manifold headers by changing of heat transfer medium stream conducting to each condenser, reducing the internal fluid volume and introducing of new structural element to manifold header design heat exchange chamber made of metal foam which increases the heat exchange surface of condenser. Presented data consist of a selection from all measurements taken during experimental operation, when solar collector with manifold header based on metal foam showed a performance increase around 25%, and reduced thermal inertia of the solar collector at operation with changing intensity of solar insolation, which leads to an overall improvement in function of the solar system. (C) 2015 Elsevier Ltd. All rights reserved.
机译:本文对标准设计的热管真空管集热器和带有金属泡沫结构元件的平行流歧管集管的集热器进行了实验热性能比较,这是作者在以前的工作中开发的。所使用的数据是在4月和5月在各种天气和气候条件下于4月和5月在斯洛伐克科希策的可再生能源中心同时运行两个相互连接的太阳能系统的实验期间获得的。具有金属泡沫结构件的歧管集管通过改变传导到每个冷凝器的传热介质流,减少内部流体体积以及将新的结构元件引入金属泡沫制成的歧管集管设计换热室,部分消除了标准设计歧管集管的缺陷。增加冷凝器的换热面积。呈现的数据包括从实验操作期间进行的所有测量中选择的一种,当带有基于金属泡沫的歧管集管的太阳能集热器表现出约25%的性能提升,并且随着日照强度的变化,太阳能集热器在运行时的热惯性降低,导致太阳能系统功能的全面改善。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Solar Energy》 |2015年第12期|359-367|共9页
  • 作者

    Rybar Radim; Beer Martin;

  • 作者单位

    Tech Univ Kosice, Ctr Renewable Energy Sources, Fac Min Ecol Proc Control & Geotechnol, Kosice 04200, Slovakia;

    Tech Univ Kosice, Ctr Renewable Energy Sources, Fac Min Ecol Proc Control & Geotechnol, Kosice 04200, Slovakia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Heat pipe evacuated tube collector; Thermal performance analysis; Metal foam; Manifold header;

    机译:热管真空管集热器;热性能分析;金属泡沫;歧管集管;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号