首页> 外文期刊>Solid state ionics >Distribution of oxygen potential in ZrO_2-based solid electrolyte and selection of reference electrode of oxygen sensor
【24h】

Distribution of oxygen potential in ZrO_2-based solid electrolyte and selection of reference electrode of oxygen sensor

机译:ZrO_2基固体电解质中氧势的分布及氧传感器参比电极的选择

获取原文
获取原文并翻译 | 示例
           

摘要

The principle for selecting the reference electrode of oxygen sensor for steelmaking was explained by the distribution formula of oxygen potential in a ZrO_2-based solid electrolyte, and this formula was evaluated under steady-state condition. The Cr/Cr_2O_3 reference electrode is better than the Mo/MoO_2 reference electrode to measure the steel melts with oxygen content lower than 300 ppm at 1600℃. The use of Mo/MoO_2 reference electrode can accurately measure the steel melts with oxygen content higher than 300 ppm, but is not suitable for measuring the steel melts with extremely low oxygen content.
机译:用ZrO_2基固体电解质中氧势的分布公式解释了用于炼钢的氧传感器参考电极的选择原理,并在稳态条件下对该公式进行了评估。 Cr / Cr_2O_3参比电极比Mo / MoO_2参比电极更好地测量1600℃下氧含量低于300 ppm的钢水。使用Mo / MoO_2参比电极可以准确地测量氧含量高于300 ppm的钢水,但不适用于测量氧含量极低的钢水。