首页> 外文期刊>Thermal engineering >Thermal Tests of the SGT5-4000F Gas-Turbine Plant of the PGU-420T Power-Generating Unit at Combined Heat and Power Plant 16 of Mosenergo
【24h】

Thermal Tests of the SGT5-4000F Gas-Turbine Plant of the PGU-420T Power-Generating Unit at Combined Heat and Power Plant 16 of Mosenergo

机译:Mosenergo联合热电厂16台PGU-420T发电机组的SGT5-4000F燃气轮机厂的热测试

获取原文
获取原文并翻译 | 示例
           

摘要

In December 2014, the PGU-420T power-generating unit was put into operation at the Combined Heat and Power Plant 16, an affiliated company of PAO Mosenergo. In 2014-2015, thermal tests of the SGT5-4000F gas-turbine plant (GTP) integrated into the power-generating unit were carried out. In the article, the test conditions are described and the test results are presented and analyzed. During the tests, 92 operating modes within a wide range of electrical loads and ambient air temperatures and operating conditions of the GTP when fired with fuel oil were investigated. In the tests, an authorized automated measuring system was applied. The experimental data were processed according to ISO 2314:2009 "Gas turbines-Acceptance tests" standard. The available capacity and the GTP efficiency vary from 266 MW and 38.8% to 302 MW and 39.8%, respectively, within the ambient air temperature range from +24 to - 12℃, while the turbine inlet temperature decreases from 1200 to 1250℃. The switch to firing fuel oil results in a reduction in the turbine inlet temperature and the capacity of the GTP. With the full load and a reduction in the ambient temperature from +24 to - 12℃, the compressor efficiency decreases from 89.6 to 86.4%. The turbine efficiency is approximately 89-91%. Within the investigated range of power output, the emissions of nitrogen oxides do not exceed 35 ppm for the gas-fired plant and 65 ppm for the fuel-oil-fired plant. Within the range of the GTP power output from 50 to 100% of the rated output, the combustion chamber operates without underburning and with hardly any CO being formed. At low loads close to the no-load operation mode, the CO emissions drastically increase.
机译:2014年12月,PGU-420T发电机组在PAO Mosenergo的关联公司热电联产16号工厂投入运行。 2014-2015年,对集成到发电装置中的SGT5-4000F燃气轮机厂(GTP)进行了热测试。在本文中,描述了测试条件,并介绍和分析了测试结果。在测试过程中,研究了92种工作模式,这些工作模式在大范围的电气负载,环境空气温度和GTP燃料​​油燃烧的工作条件下进行。在测试中,使用了授权的自动测量系统。实验数据根据ISO 2314:2009“燃气轮机验收测试”标准进行处理。在+24至-12℃的环境空气温度范围内,可用的容量和GTP效率分别从266 MW和38.8%更改为302 MW和39.8%,而涡轮机入口温度从1200降至1250℃。转换为燃烧燃油会导致涡轮机入口温度和GTP容量降低。随着满载和环境温度从+24降低到-12℃,压缩机效率从89.6%降低到86.4%。涡轮效率约为89-91%。在所研究的功率输出范围内,燃气电厂的氮氧化物排放量不超过35 ppm,燃油电厂的氮氧化物排放量不超过65 ppm。在GTP功率输出为额定输出的50%到100%的范围内,燃烧室运行时不会燃烧不足,几乎不会形成任何CO。在接近空载运行模式的低负荷下,CO排放量急剧增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号