首页> 外文期刊>Thermal engineering >Application of Variable-Frequency Electric Drives for Controlling the Drain Pumps of Low-Pressure Heaters Used in Turbine Units at Cogeneration Stations
【24h】

Application of Variable-Frequency Electric Drives for Controlling the Drain Pumps of Low-Pressure Heaters Used in Turbine Units at Cogeneration Stations

机译:变频电驱动在热电联产机组汽轮机低压加热器排污泵控制中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

Results obtained from equipping the drain pumps of low-pressure heaters used in a T-250/300-23.8 turbine unit with a standard adjustable drive are presented. It is shown that the use of this drive allows the level in the high-pressure heater to be efficiently controlled in different modes of operation with smaller consumption of energy for station auxiliaries.
机译:给出了通过为T-250 / 300-23.8涡轮机单元中使用的低压加热器的排水泵配备标准可调驱动器获得的结果。已表明,使用该驱动器可使高压加热器中的液位在不同的运行模式下得到有效控制,而站内辅助设备的能耗则较小。

著录项

  • 来源
    《Thermal engineering》 |2009年第10期|862-867|共6页
  • 作者

    I. A. Sakov;

  • 作者单位

    SKTB VKT OAO Mosenergo, Vtoroi Kozhukhovskii pr. 29, korp. 2, Moscow, 115432 Russia;