Safe operation of the Balakovo nuclear power station's Unit 2 built around a VVER-1000 reactor at a thermal power output of 3120 M W with meeting of the safety criteria and compliance with the requirements of existing regulatory documents is substantiated. Results from measurements of process parameters at a power output equal to 104% of its nominal value are presented.
机译:证实了巴拉科沃核电站2号机组围绕VVER-1000反应堆的安全运行,其热功率输出为3120 M W,符合安全标准并符合现有法规文件的要求。给出了功率输出等于其标称值的104%时过程参数的测量结果。

著录项

  • 来源
    《Thermal engineering》 |2009年第11期|963-966|共4页
  • 作者单位

    Balakovo Nuclear Power Station, Balakovo, 413866 Russia;

    Balakovo Nuclear Power Station, Balakovo, 413866 Russia;

    Balakovo Nuclear Power Station, Balakovo, 413866 Russia;

    OAO Energoatom Concern, ul. Ferganskaya 25. Moscow, 109597 Russia;

    OAO Gidropress Experimental Design Office, ul. Ordzhonikidze 21, 142103 Russia;

    OAO Gidropress Experimental Design Office, ul. Ordzhonikidze 21, 142103 Russia;

    Russian Scientific Centre Kurchatov Institute, pl. Akudemika Kurchatova 1, Moscow, 123182 Russia;

    OEP Saratov Scientific Center, Russian Academy of Sciences, ul. Politekhnicheskaya 77, Saratov, 410054 Russia;

    Russian Scientific Centre Kurchatov Institute, pl. Akudemika Kurchatova 1, Moscow, 123182 Russia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号