首页> 外文期刊>Transactions of the American nuclear society >Xe-135m Impact on the PCR Measurement of CANDU6 Core
【24h】

Xe-135m Impact on the PCR Measurement of CANDU6 Core

机译:Xe-135m对CANDU6核心PCR测量的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The impact of Xe-135m on the PCR measurement of CANDU6 core was evaluated by an in-house Xenon transient code. It was found that the change in the evaluated value of the PCR as a result of accounting for Xe-135m is quite small in case of using the TENDL-2014 library and it can reduce the evaluated CANDU6 PCR by about -0.2 pcm/%P. Nevertheless, it is very likely that consideration of Xe-135m will make the evaluated CANDU6 PCR noticeably less positive or more negative. Due to the limited nature of the cross section data used in this work, the results are subjected to unknown uncertainties at the moment and more accurate evaluation of the Xe-135m's impact is necessary. In addition, it was also found that the relevant determination of the LZC water levels is critical for a reliable determination of the CANDU6 PCR.
机译:通过内部的氙瞬态代码评估Xe-135m对CANDU6核心PCR测量的影响。发现使用TENDL-2014文库时,由于考虑到Xe-135m而导致的PCR评估值变化很小,并且可以将评估的CANDU6 PCR降低约-0.2 pcm /%P 。尽管如此,考虑使用Xe-135m很有可能会使评估的CANDU6 PCR显着降低阳性或降低阴性。由于这项工作中使用的横截面数据的性质有限,目前,结果受到未知的不确定性,因此需要对Xe-135m的影响进行更准确的评估。此外,还发现对LZC水位的相关测定对于CANDU6 PCR的可靠测定至关重要。

著录项

  • 来源
    《Transactions of the American nuclear society》 |2015年第6期|682-684|共3页
  • 作者

    Jaeha Kim; Yonghee Kim;

  • 作者单位

    Korea Advanced Institute of Science and Technology (KAIST) 291 Daehak-ro, Yuseong-gu, Daejeon, Korea, 305-701;

    Korea Advanced Institute of Science and Technology (KAIST) 291 Daehak-ro, Yuseong-gu, Daejeon, Korea, 305-701;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号