摘要

In this paper, the coupon analyses results for the coupons removed from the Zion SFP are presented. Overall, the coupons were in excellent condition. Out of the 10 coupons, only one of them showed a very small blister when initially removed from the Zion SFP. During the drying process, several coupons developed blisters; however, the drying process is not a representation of the SFP environment. Coupons also showed pits with varying depth and thickness. The dimension measurements did not show any statistically significant change. Neutron absorber materials are used in SFP to maintain criticality safety margins and areal density is the most important factor to ensure these margins are maintained. The areal density values, after residing in the Zion pool over 21 years are in excellent agreement with the pre-irradiation, as-manufactured values. The project is ongoing and the anticipated timeline for panel removal is September 2015. The panel results should shed more light on long term performance of BORAL~® as neutron absorber material in SFPs.
机译:在本文中,介绍了从Zion SFP中删除的优惠券的优惠券分析结果。总体而言,优惠券状况良好。在10张优惠券中,当最初从Zion SFP中取出时,只有其中一张显示出非常小的水泡。在干燥过程中,一些试样会产生水泡。但是,干燥过程并不代表SFP环境。优惠券还显示了具有不同深度和厚度的凹坑。尺寸测量未显示任何统计学上的显着变化。 SFP使用中子吸收材料来维持临界安全裕度,而面密度是确保维持这些裕度的最重要因素。居住在Zion池中超过21年后的面密度值与辐照后的出厂值高度吻合。该项目正在进行中,预计拆除面板的时间表为2015年9月。面板结果应进一步阐明BORAL〜®作为SFP中子吸收剂材料的长期性能。