The relationships between leak geometry and detectability are explored with a distinction between steady- and unsteady-state based techniques. Various criteria to evaluate the size and detectability of a leak are first discussed. These criteria can be useful for the benchmarking and the comparison of different techniques. Since the test conditions play a crucial rule in leak detectability, the proposed criteria take this effect into account. Furthermore, they show that while in steady-state conditions increases in system pressure enhance leak detectability, in transient state, by contrast, higher pressures tend to decrease detectability. This effect is also confirmed by experimental tests carried out at the Water Engineering Laboratory of the University of Perugia.
机译:利用基于稳态和非稳态的技术之间的区别,探索了泄漏几何形状与可检测性之间的关系。首先讨论评估泄漏的大小和可检测性的各种标准。这些标准对于基准测试和不同技术的比较可能很有用。由于测试条​​件在检漏能力中起着至关重要的规则,因此建议的标准考虑了这种影响。此外,他们表明,在稳态条件下,系统压力的增加会增强泄漏的可检测性,相反,在瞬态下,较高的压力会降低可检测性。佩鲁贾大学水工程实验室进行的实验测试也证实了这一效果。

著录项

  • 来源
    《Water Resources Management》 |2014年第13期|4583-4598|共16页
  • 作者单位

    Dipattimento di Ingegneria Civile ed Ambientale, University of Perugia, Via G. Duranti 93, 06125 Perugia, Italy;

    Dipattimento di Ingegneria Civile ed Ambientale, University of Perugia, Via G. Duranti 93, 06125 Perugia, Italy;

    Dipattimento di Ingegneria Civile ed Ambientale, University of Perugia, Via G. Duranti 93, 06125 Perugia, Italy;

    Department of Civil Engineering, University of Toronto, Toronto, Canada;

    Research Institute for Geo-Hydrological Protection, National Research Council CNR, Via Madonna Alta, 126-06128 Perugia, Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Leakage; Pipe systems; Leak detection;

    机译:泄漏;管道系统;泄漏检测;