首页> 外文期刊>Journal of the Korean Society for Applied Biological Chemistry >Detecting fludioxonil residues in brown rice and rice straw using gas chromatography-nitrogen phosphorus detector
【24h】

Detecting fludioxonil residues in brown rice and rice straw using gas chromatography-nitrogen phosphorus detector

机译:气相色谱-氮磷检测器检测糙米和稻草中的氟迪松含量

获取原文
获取原文并翻译 | 示例
       

摘要

In the present study, brown rice was steeped in 20 % wettable powder fludioxonil for 24 h, subsequently germinated, and transplanted in paddy fields. The harvested rice was tested at 156 days to detect residue levels using gas chromatography-nitrogen phosphorus detector. Validation was carried out to assess the following parameters: linearity, limit of detection and limit of quantitation (LOQ), recovery, and storage stability. Using matrix-matched calibrations, the determination coefficients were > 0.999 in both matrices. Mean recoveries were 73.5-101.0 % with relative standard deviations < 10 % in both matrices. The LOQ (0.006 mg/kg) was lower than the maximum residue limit (MRL = 0.02 mg/kg) set by the Ministry of Food and Drug Safety, Republic of Korea. The developed method was applied successfully, and no residues were detected in field-incurred rice and/or rice straw samples.
机译:在本研究中,将糙米浸入20%的可湿性粉扑氟地尼中24小时,然后发芽,然后移植到稻田中。使用气相色谱-氮磷检测器对收获的大米进行156天的检测,以检测残留水平。进行验证以评估以下参数:线性,检测限和定量限(LOQ),回收率和储存稳定性。使用矩阵匹配的校准,两种矩阵的测定系数均大于0.999。两种基质的平均回收率均为73.5-101.0%,相对标准偏差<10%。 LOQ(0.006 mg / kg)低于大韩民国食品和药品安全部设定的最大残留限量(MRL = 0.02 mg / kg)。该方法成功应用,田间稻米和/或稻草样品中均未发现残留。