In radiated emission testing based on the measurement of the total radiated power by using reverberation chambers and TEM devices, the E-field strength is correlated with the radiated power by assuming the maximum directivity of the EUT. For small EUTs, the directivity of a short dipole is often used. This paper describes how the emission E-field strength of small EUTs was measured by using the substitution method in a reverberation chamber. The results are compared with those of a GTEM-cell and an anechoic chamber. The experimental results showed an error by the assumption of the directivity in the correlated E-field strength; however, the reverberation chamber effectively measured the total radiated power. The total radiated power of the EUT with the directivity of a dipole measured by using a GTEM-cell was shifted 6dB lower than that measured with a reverberation chamber.
机译:在通过使用混响室和TEM装置测量总辐射功率的辐射测试中,通过假定EUT的最大方向性,将电场强度与辐射功率相关联。对于小型EUT,通常使用短偶极子的方向性。本文介绍了如何在混响室内使用替代方法测量小型EUT的发射电场强度。将结果与GTEM电池和消声室的结果进行比较。根据相关电场强度的方向性假设,实验结果表明存在误差。但是,混响室有效地测量了总辐射功率。与使用混响室测得的EUT的总辐射功率相比,使用GTEM单元测得的偶极子指向性降低了6dB。