Comparison and evaluation of geometric calibration methods for infrared cameras to perform metric measurements on a plane

机译:红外摄像机几何校准方法对平面进行度量测量的比较与评价

获取原文
获取原文并翻译 | 示例
           

摘要

Geometric information from infrared images can complement the information about the measured infrared radiation. However, this requires geometric camera calibration. In this work, three calibration methods for infrared cameras are compared: a direct and an iterative estimation of the transformation between image and world coordinates and a complete camera calibration method using a specifically designed calibration target. The three methods are compared and the obtained performance for metric measurements on a plane is evaluated. The results indicate acceptable performance in the three cases, with the complete method clearly outperforming the two others with an average error of only 0.060 mm, which represents 0.08% error of the measured distance. (C) 2018 Optical Society of America
机译:来自红外图像的几何信息可以补充有关测量的红外辐射的信息。 但是,这需要几何相机校准。 在这项工作中,比较了三个红外摄像机的校准方法:直接和迭代估计图像和世界坐标之间的变换以及使用专门设计的校准目标的完整相机校准方法。 比较了三种方法,评估了在平面上进行的测量度测量的性能。 结果表明了三种情况下的可接受的性能,完整的方法明显优于两个其他误差仅为0.060毫米的两种情况,这表示测量距离的0.08%误差。 (c)2018年光学学会

著录项

  • 来源
    《Applied optics》 |2018年第18期|共10页
  • 作者单位

    Univ Oviedo Dept Comp Sci &

    Engn Gijon 33204 Spain;

    Laval Univ Comp Vis &

    Syst Lab Quebec City PQ G1 V 0A6 Canada;

    Laval Univ Comp Vis &

    Syst Lab Quebec City PQ G1 V 0A6 Canada;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 应用;
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号