首页> 外文期刊>Applied optics >Strategies for laser-induced fluorescence detection of nitric oxide in high-pressure flames. II. A-X(0,1) excitation
【24h】

Strategies for laser-induced fluorescence detection of nitric oxide in high-pressure flames. II. A-X(0,1) excitation

机译:高压火焰中的激光诱导荧光检测荧光检测的策略。 II。 A-X(0,1)激励

获取原文
获取原文并翻译 | 示例
           

摘要

A-X(0,1) excitation is a promising new approach for NO laser-induced fluorescence (LIF) diagnostics at elevated pressures and temperatures. We present what to our knowledge are the first detailed spectroscopic investigations within this excitation band using wavelength-resolved LIF measurements in premixed methane/air flames at pressures between 1 and 60 bar and a range of fuel/air ratios. Interference from O_(2) LIF is a significant problem in lean flames for NO LIF measurements, and pressure broadening and quenching lead to increased interference with increased pressure. Three different excitation schemes are identified that maximize NO/O_(2) LIF signal ratios, thereby minimizing the O_(2) interference. The NO LIF signal strength, interference by hot molecular oxygen, and temperature dependence of the three schemes are investigated.
机译:A-X(0,1)激发是在升高的压力和温度下没有激光诱导的荧光(LIF)诊断的有希望的新方法。 我们介绍了我们所知的是在该激发带内的第一种详细的光谱调查,在预混合的甲烷/空气火焰中在1至60巴的压力下和一系列燃料/空气比的压力下的波长分辨的生长测量。 来自O_(2)LIF的干扰是没有生命测量的贫火焰中的显着问题,并且压力扩大和淬火导致对增加的压力增加的干扰。 识别出三种不同的激励方案,其最大化NO / O_(2)LIF信号比率,从而最小化O_(2)干扰。 研究了热分子氧的无生命信号强度,干扰以及三种方案的温度依赖性。