Ventricular septal ruptures are an uncommon complication following acute myocardial infarction. Operative repair, utilizing a patch for closure of the defect, is the primary treatment modality to achieve hemodynamic stability. The use of an extracellular matrix derived from small intestinal submucosa as a scaffold for tissue repair is becoming increasingly common. Here, we present the case of a 58-year-old female found to have a ventricular septal rupture and posterior left ventricular aneurysm following late presentation after a myocardial infarction that required operative repair with a CorMatrix patch. Upon readmission for dyspnea and poor exercise tolerance several months later, the patch was subsequently found to have near-completely reabsorbed. There is a paucity of long-term outcomes data following the use of CorMatrix for septal defects, with rare reports of such reabsorption. Further study is required to identify the incidence and implications of such findings.
机译:室间隔破裂是急性心肌梗死后罕见的并发症。手术修复是实现血流动力学稳定的主要治疗方式,利用补片闭合缺损。利用来源于小肠粘膜下层的细胞外基质作为组织修复的支架越来越普遍。我们在此报告一例58岁女性患者,在心肌梗死后晚期出现室间隔破裂和左后室壁瘤,需要使用CorMatrix补片进行手术修复。几个月后,因呼吸困难和运动耐受性差再次入院时,发现贴片几乎完全被吸收。在使用CorMatrix治疗间隔缺损后,缺乏长期结果数据,很少有此类再吸收的报道。需要进一步研究来确定这些发现的发生率和影响。