Toward Harmonized Treadmill-Based Validation of Step-Counting Wearable Technologies: A Scoping Review

机译:朝着阶梯计数的可穿戴技术的统一跑步机的验证:范围审查

获取原文
获取原文并翻译 | 示例
           

摘要

The authors conducted a scoping review as a first step toward establishing harmonized (ie, consistent and compatible), empirically based best practices for validating step-counting wearable technologies. Purpose: To catalog studies validating step-counting wearable technologies during treadmill ambulation. Methods: The authors searched PubMed and SPORTDiscus in August 2019 to identify treadmill-based validation studies that employed the criterion of directly observed (including video recorded) steps and cataloged study sample characteristics, protocol details, and analytical procedures. Where reported, speed- and wear location-specific mean absolute percentage error (MAPE) values were tabulated. Weighted median MAPE values were calculated by wear location and a 0.2-m/s speed increment. Results: Seventy-seven eligible studies were identified: most had samples averaging 54% (SD = 5%) female and 27 (5) years of age, treadmill protocols consisting of 3 to 5 bouts at speeds of 0.8 (0.1) to 1.6 (0.2) m/s, and reported measures of bias. Eleven studies provided MAPE values at treadmill speeds of 1.1 to 1.8m/s; their weighted medianMAPE values were 7% to 11% for wrist-worn, 1% to 4% for waist-worn, and <= 1% for thigh-worn devices. Conclusions: Despite divergent study methodologies, the authors identified common practices and summarized MAPE values representing device step-count accuracy during treadmill walking. These initial empirical findings should be further refined to ultimately establish harmonized best practices for validating wearable technologies.
机译:作者进行了范围界定审查,作为建立协调(即一致和兼容)的、基于经验的最佳实践的第一步,以验证步数可穿戴技术。目的:对在跑步机行走期间验证步数可穿戴技术的研究进行分类。方法:作者于2019年8月搜索了PubMed和SPORTDiscus,以确定基于跑步机的验证研究,这些研究采用了直接观察(包括视频记录)步骤和编目研究样本特征、方案细节和分析程序的标准。在报告的地方,速度和磨损位置特定的平均绝对百分比误差(MAPE)值被制成表格。通过磨损位置和0.2m/s的速度增量计算加权中值MAPE值。结果:共确定了77项符合条件的研究:大多数研究的样本平均为54%(SD=5%)女性和27(5)岁,跑步机方案包括以0.8(0.1)到1.6(0.2)m/s的速度进行3到5次比赛,并报告了偏倚测量。11项研究提供了跑步机速度为1.1至1.8m/s时的MAPE值;腕部佩戴时,他们的加权medianMAPE值为7%至11%,腰部佩戴时为1%至4%,大腿佩戴时<=1%。结论:尽管研究方法存在分歧,但作者确定了常见做法,并总结了代表跑步机行走期间设备步数准确性的MAPE值。这些初步的实证结果应该进一步完善,以最终建立验证可穿戴技术的统一最佳实践。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号