Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines

机译:Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines

获取原文
获取原文并翻译 | 示例
           

摘要

The current research results indicate that the insulator's insulation performance has a very important influence on the back-flashover lightning withstand performance of UHVDC transmission lines, especially for +/- 800 kV voltage level. However, it is not clear which factors will influence the insulation performance of the insulator, and the influencing mechanism is also not clear yet. To figure out this problem, the insulator's insulation performance under different conditions has been deeply analyzed and considered to reveal the influence mechanism in this paper, such as the surface hydrophobicity, pollution degree, and the string type. Firstly, the insulator's model is established using COMSOL software, and the lightning impulse voltage of insulator is calculated and verified with the corresponding experimental data. Then, the +/- 800 kV UHVDC transmission lines model is constructed using PSCAD software, and back-flashover lightning withstand level and back-flashover rate are calculated by considering the above lightning impulse voltage as the threshold of flashover. Finally, the back-flashover lightning withstand performance of +/- 800 kV UHVDC transmission lines is deeply analyzed based on different insulators. The simulation results demonstrate that the back-flashover lightning withstand performance of +/- 800 kV UHVDC transmission lines is obviously weakened with the increase of the pollution degree and slightly weakened with the decrease of the surface hydrophobicity. Considering the same pollution degree, the V-type string insulator has the least influence, while the II-type string insulator has the greatest influences on the back-flashover lightning withstand performance of +/- 800 kV UHVDC transmission lines. The research results are beneficial for providing theoretical basis for stable operation and reliable power supply of +/- 800 kV UHVDC transmission lines.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号