首页> 外文期刊>Kobelco Technology Review >Utilization of Cold Energy in Intermediate Fluid-type Vaporizer (IFV) for LNG Receiving Terminals
【24h】

Utilization of Cold Energy in Intermediate Fluid-type Vaporizer (IFV) for LNG Receiving Terminals

机译:Utilization of Cold Energy in Intermediate Fluid-type Vaporizer (IFV) for LNG Receiving Terminals

获取原文
获取原文并翻译 | 示例
       

摘要

Intermediate fluid-type vaporizers (IFVs), a type of LNG vaporizers, have been used as vaporizers that enable the utilization of the cold energy of LNG in, for example, cryogenic power generation. Recently, there is an increasing number of cold energy utilization projects using chilled water from an IFV for, e.g., the intake air cooling of gas turbines. This paper introduces the latest trends in LNG receiving terminals including offshore receiving terminals, the features of IFVs as LNG vaporizers for cold energy utilization, and examples of cold energy utilization using IFV including gas-turbine intake air cooling.