首页> 外文期刊>Reviews in endocrine & metabolic disorders >Diagnostic accuracy of bilateral inferior petrosal sinus sampling using desmopressin or corticotropic- releasing hormone in ACTH-dependent Cushing's syndrome: A systematic review and meta-analysis
【24h】

Diagnostic accuracy of bilateral inferior petrosal sinus sampling using desmopressin or corticotropic- releasing hormone in ACTH-dependent Cushing's syndrome: A systematic review and meta-analysis

机译:Diagnostic accuracy of bilateral inferior petrosal sinus sampling using desmopressin or corticotropic- releasing hormone in ACTH-dependent Cushing's syndrome: A systematic review and meta-analysis

获取原文
获取原文并翻译 | 示例
       

摘要

The current gold standard diagnostic method for Cushing disease (CD) is bilateral inferior petrosal sinus sampling (BIPSS) after corticotropin-releasing hormone (CRH) stimulation. Due to shortages of CRH, BIPSS has been performed with desmopressin (DDAVP) instead. The objective of this systematic review and meta-analysis was to estimate the diagnostic accuracy of BIPSS using DDAVP or CRH for the differential diagnosis of Cushing's syndrome (CS). A literature review was done in PubMed, Scopus, EMBASE, and google scholar databases to derive summary estimates of the overall diagnostic sensitivity and accuracy of BIPSS using DDAVP or CRH in Cushing's syndrome. Pooled sensitivity, specificity, diagnostic odds ratio and summary receiver operating characteristic curves (SROC) for differential diagnosis of Cushing's syndrome in the random-effects models, were computed. Overall, 11 different studies with a total of 612 participants, were eligible for the analysis. Five articles with data on BIPSS using DDAVP, 5 papers on BIPSS using CRH, and another one evaluated the results of stimulation using DDAVP, with or without CRH, for differential diagnosis of Cushing's syndrome. The pooled (95% CI) sensitivity and specificity of BIPSS using DDAVP, were 96% (91-98%) and 1.00 (0.00-1.00), respectively. The area under the SROC curve was 0.95. The pooled (95% CI) sensitivity and specificity of BIPSS using CRH, were 98% (92-99%) and 1.00 (0.00-1.00), respectively, and the area under the SROC curve was 0.98. The I-2 index (95% CI) was 0% (0-100%) for both BIPSS using DDAVP and using CRH. As a result, DDAVP stimulation is a safe, effective, less expensive, valuable and available alternative to CRH in the setting of BIPSS for all age groups of patients with CS. Registration code in PROSPERO: CRD42021292531.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号