首页> 外文期刊>The Journal of Prosthetic Dentistry >Effect of different surface treatments on the bond strength of milled polyetheretherketone posts
【24h】

Effect of different surface treatments on the bond strength of milled polyetheretherketone posts

机译:Effect of different surface treatments on the bond strength of milled polyetheretherketone posts

获取原文
获取原文并翻译 | 示例
           

摘要

Statement of problem. Polyetheretherketone (PEEK) can be used as a framework material for removable and fixed dental prostheses. However, information about the use of PEEK as a postand-core restoration is scarce. Purpose. The purpose of this in vitro study was to evaluate the effect of different surface treatments on the push-out bond strength of milled polyetheretherketone posts to resin cement. Material and methods. Sixty intact human maxillary central incisors were selected and endodontically treated, and standardized post spaces were prepared. Sixty PEEK posts were milled from a prefabricated PEEK blank by using a computer-aided design and computer-aided manufacturing (CAD-CAM) system and divided into 3 groups (n=15) according to the surface treatment: acid etching by using 98% sulfuric acid (AE); airborne-particle abrasion by using 50-mu m Al2O3 (AA); nonthermal plasma treatment (NTP); in addition, PEEK posts (n=15) received no treatment (NT) and served as a control. All posts were bonded by using a self-adhesive resin cement. Three sections (coronal, middle, and apical) were obtained for each specimen. Push-out bond strength measurements (MPa) for each section were recorded by using a universal testing machine at a crosshead speed of 0.5 mm/min until failure occurred. The post-cement interfaces and failure modes were evaluated by using scanning electron microscopy. The data obtained were statistically analyzed by using 1-way ANOVA and the pair-wise Tukey (HSD) test to study the difference between group mean values (alpha=.05). Results. The overall mean +/- standard deviation of the push-out bond strength was 11 +/- 2 MPa for AE group, 6 +/- 1 MPa for AA group, 5 +/- 1 MPa for NTP group, and 3 +/- 1 MPa for NT group. A statistically significant difference was found among all groups subjected to different surface treatments as indicated by the ANOVA test (P.05). Moreover, a significant difference was observed among all root sections (P<.001). Conclusions. Surface treatment of PEEK posts with 98% sulfuric acid for 60 seconds showed significantly higher bond strength values than those in other groups. The bond strength of PEEK posts to resin cement was significantly higher in the coronal section than that in other sections.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号