首页> 外文期刊>The Journal of Prosthetic Dentistry >In vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing
【24h】

In vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing

机译:In vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing

获取原文
获取原文并翻译 | 示例
           

摘要

Statement of problem. Polyetheretherketone (PEEK) has been advocated to replace metal components in dentistry. Although PEEK is a high-performance polymer with a white color, adequate biological response, and resistance to fracture, data to support PEEK as an alternative material for implant abutments are lacking. Purpose. The purpose of this in vitro study was to assess the mechanical and functional properties of PEEK implant abutments as a nonmetallic alternative to titanium abutments, which presents esthetic limitations and greater difficulty to customize clinically. Material and methods. Implant abutments manufactured by using PEEK (n=24) or titanium grade 5 (n=24) were attached to MIS Implants type M4 3.75x16 mm with an internal screw tightened to 25 Ncm. Screw loosening and microleakage was assessed by submersion in a 2% methylene blue solution for 48 hours at 37 degrees C. Both groups were compared with and without applying dynamic loading; fatigue testing was performed following the International Organization for Standardization (ISO) 14801:2016 standard. All specimens were observed under a stereomicroscope at x8 magnification. Statistically significant differences among the PEEK and titanium implant abutments were tested with 2-factor ANOVA and the chi-square analysis for nonpaired and paired data, respectively (alpha=.05). Results. The implant abutments made of titanium were better in all mechanical tests. The torque loss of titanium abutments was approximately 10%, while PEEK showed a significantly higher (P<.05) torque loss of up to 50%. Moreover, 91.6% of the titanium abutments did not present microleakage, while there was no specimen of PEEK abutments without microleakage, once subjected to dynamic loading (P<.05). Conclusions. Titanium implant abutments (Ti6Al4V) were better in all tests performed. However, PEEK abutments may be suitable for long-term interim restorations, especially in the anterior area, in patients without parafunction.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号