首页> 外文期刊>The Journal of Prosthetic Dentistry >Effects of build orientation on adaptation of casting patterns for three-unit partial fixed dental prostheses fabricated by using digital light projection
【24h】

Effects of build orientation on adaptation of casting patterns for three-unit partial fixed dental prostheses fabricated by using digital light projection

机译:Effects of build orientation on adaptation of casting patterns for three-unit partial fixed dental prostheses fabricated by using digital light projection

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose. The purpose of this in vitro study was to evaluate the effect of build orientation on the adaptation of casting patterns fabricated by digital light projection (DLP). Material and methods. A 3-unit partial fixed dental prosthesis with mandibular left second premolar and second molar abutment teeth was scanned and virtually designed with a computer-aided design software program. The cement space was designed to be 30 gm. Specimens were fabricated with 3 build orientations: 0 degrees (with the occlusal surface parallel to the platform), 30 degrees, and 45 degrees (by rotating the file along the long axis). The casting patterns were fabricated by using DLP (Cara Print 4.0) with a photopolymerizable monomer (dima Print Cast Q). Photopolymerization, cleaning, and postpolymerization processes were performed according to the manufacturer's instructions. The adaptation of the specimens was examined by using a silicone replica method. The vertical marginal discrepancy and axial wall, occlusal, and marginal gaps were measured by using a digital measuring microscope. The effect of build orientation at each cross-sectional area was statistically analyzed by using the Kruskal-Wallis test followed by the pairwise Wilcoxon rank sum test with Bonferroni correction (c=.05). Results. Excess polymerized resin was observed along the intaglio buccal wall at build orientations of 30 degrees and 45 degrees. Vertical marginal discrepancies in the buccolingual section ranged from -50 to 248 gm, while those in the mesiodistal section ranged from -25 to 182 gm. The gaps in the buccolingual section ranged from 0 to 236 gm, while those in the mesiodistal section ranged from 0 to 177 gm. According to the observation of vertical marginal discrepancies and gaps, the 30-degree specimens inclined during insertion, and the 45-degree specimens were not completely seated. However, the marginal gaps of the 0- and 30-degree specimens were within the clinically acceptable limit of 120 gm. Conclusions. The limited data indicated that the build orientation influenced the adaptation of casting patterns for 3-unit partial fixed dental prostheses fabricated by using DLP. A build orientation of 0 degrees is recommended for fabricating casting patterns for 3-unit partial fixed dental prostheses because no excess polymerization of the intaglio buccal wall was observed. (J Prosthet Dent 2022;128:1047-54)

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号