首页> 外文期刊>同誌社大学理工学研究報告 >Effect of Current Injection Cable on Lightning Surge Measurement for Scaled Circuit
【24h】

Effect of Current Injection Cable on Lightning Surge Measurement for Scaled Circuit

机译:Effect of Current Injection Cable on Lightning Surge Measurement for Scaled Circuit

获取原文
获取原文并翻译 | 示例
           

摘要

Transient characteristic of a current injection cable, which is used for a surge measurement, is investigated in this paper. Measurements are carried out in order to confirm the accuracy of a numerical simulation by means of a circuit analysis program, Electromagnetic Transients Program (EMTP). The measured results are physically explained by theoretical calculations using travelling wave theory. The characteristic impedance of the current injection cable is finally calculated. The results show that the recursive convolution line model, which is known as Semlyen's frequency-dependent line model, can be used to represent the current injection cable. If the core is terminated by a low impedance and the sheath is open-circuited at the receiving-end, an earth-return mode is generated by a reflection at the receiving end from a coaxial mode component.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信