首页> 外文期刊>physics in medicine and biology >Neutron dosimetry in theIin vivo/Imeasurement ofintrathyroidal iodine in man by activation analysis
【24h】

Neutron dosimetry in theIin vivo/Imeasurement ofintrathyroidal iodine in man by activation analysis

机译:Neutron dosimetry in theIin vivo/Imeasurement ofintrathyroidal iodine in man by activation analysis

获取原文
           

摘要

A collimated beam of neutrons from a reactor was used to irradiate thethyroid, inducingl28I which can be detected by external counting. Neutron dosimetrystudies have been carried out with the unmodified beam and also using a boron filterto absorb incident thermal neutrons. Five methods were used to provide doseestimates and the results were in reasonable agreement, giving for a clinical examination at 20 kw reactor power a mean dose-equivalent and standard error of 20.41.1rem for the filtered beam, and 24.11.2 rem for the unmodified beam due to neutronsat the thyroid. The concurrent-ray dose is 2.10.2 rem. The dose to the eyesand gonads is less than 1 of the thyroid dose.

著录项

  • 来源
    《physics in medicine and biology》 |1969年第3期|471-480|共页
  • 作者

    K Boddy; J A Dennis; R C Lawson;

  • 作者单位

    Scottish Research Reactor Centre, East Kilbride, Glasgow, UK;

    Health Physics and Medical Division, U.K.A.E.A., Harwell, UK;

    U.K.A.E.A., Chapelcross Works, Annan, Dumfriesshire, UK;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 英语
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号