首页> 外文期刊>heat transfer engineering >Errors due to the Length of Arc Idealization in Convective Extended Surfaces
【24h】

Errors due to the Length of Arc Idealization in Convective Extended Surfaces

机译:Errors due to the Length of Arc Idealization in Convective Extended Surfaces

获取原文
           

摘要

An analysis of the errors due to the length of arc idealization in convective extended surfaces is presented. Longitudinal fins, spines, and annular fins of triangular profile are considered. It is shown that in fins that are designed according to the criteria established by Razelos and Georgiou 7, the resulting errors are negligibly small. These criteria suggest that fins should be designed with order of magnitude of aspect and Biot numbers of u = O(1) and Bi = O(0.01). It is also shown that for spines and annular fins only the Biot number restriction suffices to warrant negligible errors.

著录项

  • 来源
    《heat transfer engineering》 |1994年第3期|19-24|共页
  • 作者

    P. RAZELOS; E. GEORGIOU;

  • 作者单位
  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 英语
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com