Automatic mask alignment in the theta direction using moire sensors is reported. The relation between small angular displacement and linear displacement is clarified. A computer-controlled angular alignment system is developed. A desired alignment position is easily set by a computer. In our experimental condition, angular accuracy of the order of 14*10-7rad is realized by automatic computer control.