...
首页> 外文期刊>Environmental Science & Technology: ES&T >Electrochemical study of arsenate and water reduction on iron media used for arsenic removal from potable water
【24h】

Electrochemical study of arsenate and water reduction on iron media used for arsenic removal from potable water

机译:Electrochemical study of arsenate and water reduction on iron media used for arsenic removal from potable water

获取原文
获取原文并翻译 | 示例
           

摘要

Zerovalent iron filings have been proposed as a filter medium for removing As(III) and As(V) compounds from potable water. The removal mechanism involves complex formation of arsenite and arsenate with the iron surface and with iron oxides produced from iron corrosion. There is conflicting evidence in the literature on whether As(V) can be reduced to As(III) by iron filter media. This research uses electrochemical methods to investigate the redox reactions that occur on the surface of zerovalent iron in arsenic solutions. The effect of arsenic on the corrosion rate of zerovalent iron was investigated by analysis of Tafel diagrams for iron wire electrodes in anaerobic solutions with As(V) concentrations between 100 and 20,000 μg/L As(V) reduction in the absence of surface oxides was investigated by analysis of chronoamperometry profiles for iron wire electrodes in solutions with As(V) concentrations ranging from 10 000 to 10{sup}6μg/L The effect of pH on As(V) reduction was investigated by analyses of chronopotentiometry profiles for iron wire electrodes at pH values of 2, 6.5, and 11. For freely corroding iron, the presence of As(III) and As(V) decreased the iron corrosion rate by a factor of 5 as compared to that in a 3 mM CaSO{sub}4 blank electrolyte solution. The decrease in corrosion rate was independent of the arsenic concentration and was due to the blocking of cathodic sites for water reduction by arsenic compounds chemisorbed to the iron surface. The chronoamperometry and chronopotentiometry experiments showed that elevated pH and increased As(III) to As(V) ratios near the iron surface decreased the thermodynamic favorability for As(V) reduction. Therefore, reduction of As(V) occurred only at potentials that were significantly below the apparent equilibrium potentials based on bulk solution pH values and As(III) to As(V) ratios. The potentials required to reduce more than 1 of the As(V) to As(III) were below those that are obtainable in freely corroding iron media. This indicates that there will be minimal or no reduction of As(V) in iron media filters under conditions relevant to potable water treatment.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号