AbstractThe ripple‐free deadbeat control problem for SISO plants subjected to arbitrary reference signals is considered. The trade‐off between the settling time and the integral square error between the system output and reference signal is investigated. Given a specific order of the controller, it is shown how to design an optimal ripple‐free deadbeat controller. An illustrative example is presented to show the feasibility of the proposed algo