首页> 外文期刊>Key engineering materials >An Experimental Investigation of Interface Fracture Characteristic of APS Thermal Barrier Coating System under Bending at 1000 ℃
【24h】

An Experimental Investigation of Interface Fracture Characteristic of APS Thermal Barrier Coating System under Bending at 1000 ℃

机译:An Experimental Investigation of Interface Fracture Characteristic of APS Thermal Barrier Coating System under Bending at 1000 ℃

获取原文
获取原文并翻译 | 示例
           

摘要

This paper investigated the thermo-mechanical bending failure characteristic of air plasma-sprayed (APS) thermal barrier coating (TBC) system at 1000 ℃ by three-point bending test. A through-width surface pre-crack on the centre surface of the top ceramic coating (TC) in TBC sample was firstly designed and made by air plasma spraying technology. The fracture characteristic and spallation phenomena of the TBC were investigated under bending test in air at 1000 ℃. The effects of constant displacement rate, span width of bending equipment and thermal aging time on the thermo-meehanical bending failure of the APS TBC system were slight at 1000 ℃. Using SEM observations and EDX analysis, the interface cracks initiation, propagation and coalescence were discussed in detail. Furthermore, the fracture surface located within the TBC close to the TBC/TGO interface for all APS TBC samples under bending at 1000 ℃.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号