首页> 外文期刊>Key engineering materials >Evaluation of Nuclear Piping Failure Frequency in Korean Pressurized Water Reactors
【24h】

Evaluation of Nuclear Piping Failure Frequency in Korean Pressurized Water Reactors

机译:Evaluation of Nuclear Piping Failure Frequency in Korean Pressurized Water Reactors

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this paper is to evaluate the piping failure frequency based on the piping failure events in Korean pressurized water reactors (PWRs) until the end of 2003. Two types of the piping failure frequencies including the piping damage frequency and the piping rupture frequency are considered in this study. The piping damage frequency for the failed piping system was estimated by using the piping population data such as the weld count or the base metal count. The piping rupture frequency related to the initiating event in a probabilistic safety assessment (PSA) was evaluated by using both the Bayesian approach (Method 1) and the conditional rupture probability approach (Method 2). In the Bayesian approach, two methods using Jeffreys noninformative prior (Method 1-1) and prior distributions based on the results in NUREG/CR-5750 (Method 1-2) were considered. Thirty piping failure events in ASME safety class pipings of Korean PWRs were identified and analyzed in this study. The results showed that the piping damage frequency for the events ranged from 5.42E-3/cr.yr to 2.77E-5/cr.yr. Three kinds of initiating events including the very small LOCA, the feedwater line break, and the flood are evaluated for Korean PWRs. The results for the piping rupture frequency in Korean PWRs were as follows: 1) The mean piping rupture frequency of the very small LOCA event ranged from 3.6E-3/cr.yr to 1.2E-2/cr.yr, the feedwater line break event from 3.6E-3/cr.yr to 2.5E-2/cr.yr, and the flood event from 7.8E-4/cr.yr to 3.6E-3/cr.yr. The mean piping rupture frequencies of the very small LOCA and feedwater line break events were higher than that of the flood event by one order of a magnitude. 2) Method 2 gave conservative results in the very small LOCA and feedwater line break events compared to Method 1-1 or Method 1-2, while Method 1-1 gave conservative results in the flood event. 3) The order of magnitudes in the mean piping rupture frequencies of the very small LOCA, the feedwater line break, and the flood in Korean PWRs were similar to those in the U.S. PWRs.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号