首页> 外文期刊>Review of Scientific Instruments >Internal toroidal field measurements on the helicity injected tokamak using the transient internal probe
【24h】

Internal toroidal field measurements on the helicity injected tokamak using the transient internal probe

机译:Internal toroidal field measurements on the helicity injected tokamak using the transient internal probe

获取原文
获取原文并翻译 | 示例
           

摘要

Measurements of the local toroidal magnetic field have been achieved on the helicity injected tokamak (HIT) using the transient internal probe (TIP). HIT is a low aspect (a = 1.5, R =0.35 m) ratio tokamak designed to study steady state current drive. The TIP diagnostic involves accelerating a small diamond clad magneto-optic probe through the plasma at high velocities (~2 km/s) using a light gas gun. The local field is obtained by illuminating the probe with a laser and measuring the amount of Faraday rotation in the reflected beam. Measurements were conducted using unclad magneto-optic probes directed along a chord tangent to the toroidal field. Plasma conditions were typically n↓(e)~7×10↑(19) m↑(-3) and T↓(e)~40-80 eV. Measurement uncertainty is less than 2. No changes in plasma parameters were observed during the first 200 ms (~40 cm) of probe travel in the plasma. A temporary dip in plasma current, probably due to ablation of the retroreflecting material 0n the probe, is observed as the probe exits the plasma. Density is unaffected by the presence of the probe in the plasma. No long term deleterious effects to tokamak performance were observed as the TIP diagnostic was found to be quite compatible with the tokamak. #1997 American Institute of Physics. S0034-6748(97)53501-5

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号