首页> 外文期刊>Clinical and diagnostic laboratory immunology >Comparison of In-House and Commercial Slides for Detection by Immunofluorescence of Immunoglobulins G and M against Bartonella henselae and Bartonella quintana.
【24h】

Comparison of In-House and Commercial Slides for Detection by Immunofluorescence of Immunoglobulins G and M against Bartonella henselae and Bartonella quintana.

机译:

获取原文
获取原文并翻译 | 示例
           

摘要

We compared the sensitivities and specificities of indirect fluorescent antibody tests developed in our laboratory and commercially available from Focus Technologies (FT; formerly MRL Diagnostic) for detection of serum antibodies to Bartonella spp. Serum samples tested were from patients with culture- or PCR-confirmed Bartonella quintana or B. henselae infections causing cat scratch disease (CSD), chronic bacteremia, or endocarditis. At a cutoff titer of 64, the FT test had higher sensitivity than our in-house test in detecting anti-B. henselae immunoglobulin G (IgG) antibodies in CSD patients (91.2 versus 52.9; P /=1,024 were found only in endocarditis patients and not in CSD patients. With the FT test, 19.1 of CSD patients had titers of IgG against B. henselae of >/=1,024 (P /=1,024 were present in 75 of serum samples, but only in 16.7 of serum samples with the FT test (P = 0.004). Since each test has advantages over the other, the serological diagnosis of Bartonella infections would benefit if both tests were used concurrently.

著录项