首页> 外文期刊>Review of Scientific Instruments >Time-domain reflectometry of high-voltage nonlinear loads with picosecond resolution
【24h】

Time-domain reflectometry of high-voltage nonlinear loads with picosecond resolution

机译:

获取原文
获取原文并翻译 | 示例
           

摘要

The construction and characterization of a measuring module for high voltage time-domain reflectometry with picosecond resolution is presented. The device provides registration of low-distortion reflections from the load at conditions of irregular shape and pronounced instability of an incident probing pulse with amplitude of hundreds of kilovolts and a width/front up to ~2 ns. This is achieved with registration of differential reflecting signals by using two voltage probes, whose original signals are shifted in time and have a calibrated delay. Specially designed voltage dividers based on coaxial coupled lines with equalized dielectric constant of insulation meet the requirements of voltage probes identity. Reflectometry allows one to study dynamic changes of the loads for a specific time range of ~10~(-10) s and faster. An example of reflectometry-based analysis for variations in breakdown development rate of atmospheric discharge gap supplied with the pulses of ~100-kV amplitude and a front slope of ~4 × 10~(14) V/s is presented.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号