Objectives : We aimed to compare the performance of pulse-oximetry screening in detecting nonductus-dependent cyanotic congenital heart defects (CCHDs). Methods : In a prospective cross-sectional study, we recorded post ductal saturation of neonates (< 48 h old) born at a community hospital in northern India. Subsequently, all underwent clinical examination and echocardiogram by a trained cardiologist. A saturation < 95 was considered a "failed " screen. Results : Ten neonates were identified to have nonductus-dependent CCHD on echocardiogram, five of whom had passed pulse-oximetry screen. This translated to a sensitivity of 50 (95 confidence interval CI 23.7-76.3) and a positive predictive value of 0.08 (95 CI 0.03-0.2), both of which were significantly less compared to that in ductus-dependent congenital heart defect. Conclusions : Up to half of the nonductus-dependent CCHD may be missed if screened only using pulse oximetry. Parents should not be reassured regarding the absence of CCHD only based on a "pass " in pulse-oximetry screening.