首页> 外文期刊>Mikrochimica Acta: An International Journal for Physical and Chemical Methods of Analysis >Kinetic-potentiometric assay of formaldehyde in pharmaceutical and industrial samples,.monitored by copper solid ion selective electrode,after its reaction with the copper(II)-bis-(ethylenediamine) complex
【24h】

Kinetic-potentiometric assay of formaldehyde in pharmaceutical and industrial samples,.monitored by copper solid ion selective electrode,after its reaction with the copper(II)-bis-(ethylenediamine) complex

机译:铜和固体离子选择性电极与铜(II)-双-(乙二胺)络合物反应后,用动力学监测法测定药物和工业样品中的甲醛

获取原文
获取原文并翻译 | 示例
           

摘要

A kinetic-potentiometric method is described for the quantitative assay of formaldehyde(HCHO) in pharmaceutical and industrial preparations.It is based on the reaction of HCHO with(ethylenediamine)-Cu(II)-sulfate[Cu(CH2NH2)2(H2O)2]·SO4.The changes in potential,resulting from the release of the Cu(II) cations,are monitored with a Cu(II)-ion selective electrode.The calibration curve for the HCHO is linear in the concen tration range 50-250 mg L-1,with a limit of detection of 8.5 mgL-1.The method shows very good reproducibil ity with an RSD of 2.6% for successive injections(n=5) of 150 mg LT-1 HCHO primary solution,while it is inter ference free.The method was successfully tested in var ious industrial and pharmaceutical preparations.
机译:介绍了一种动力学电位法,用于定量测定制药和工业制剂中的甲醛(HCHO),该方法基于HCHO与(乙二胺)-硫酸铜(II)-硫酸铜[Cu(CH2NH2)2(H2O)的反应2]·SO4。使用Cu(II)离子选择性电极监测由于释放Cu(II)阳离子而引起的电位变化。HCHO的校准曲线在浓度范围50- 250 mg L-1,检测限为8.5 mgL-1。该方法显示出很好的重现性,连续进样(n = 5)150 mg LT-1 HCHO初次溶液时的RSD为2.6%。该方法无干扰。该方法已在各种工业和药物制剂中成功进行了测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号